Assembly and operating instructions
Read the instructions prior to performing any task!
REMKO RKL 491 DC
Local inverter room air conditioner in split design
0074-2014-01 Edition 1, en_GB
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - REMKO RKL 491 DC

Assembly and operating instructionsRead the instructions prior to performing any task!REMKO RKL 491 DCLocal inverter room air conditioner in split des

Page 2

IR21101214FANTEMP.ON/OFFFUZZYCTIMERMODE17Fig. 4: Infrared remote controlIR Infrared transmitterCooling mode ( )1. Switch the unit on by means of th

Page 3 - Table of contents

5 Installation Installation instructionsThe device is supplied in a fully operational condi-tion and is equipped as standard with a 3.0 m longconne

Page 4

Fig. 7: Example assembly outdoor unitMounting on an external wall with wall bracketn Fasten to the wall using the supplied wallbracket.n Hook the outd

Page 5

20 cmmax. 1,8 mFig. 10: Max. assembly heightExternal wall mounting with fastening strapsFastening straps are an additional option formounting the outd

Page 6

6 Connecting line The connecting line is connected to the indoor unitwith quick-release couplings. This provides thefacility to disconnect the conn

Page 7 - Technical data

In doing so, the following procedure must beadhered to:1. Switch the unit off.2. Pull the power plug out of the socket.3. Remove the 2 screws from the

Page 8

NOTICE!Never twist the the fixed upper section.12. Screw continuously until the connection isdisconnected. NOTICE!Do not stop screwing in the event t

Page 9 - Operation

7 Electrical connection Electrical connection diagramFig. 17: Electrical connection diagramPCB1 Control boardPCB2 Main boardSM Swing motorFM1 Vapo

Page 10 - REMKO RKL

8 Troubleshooting and customer service The unit has been manufactured using state-of-the-art production methods and tested several times toensure

Page 11 - Installation

Error codes Fault description / note38 Low power AC39 High power AC(A)40 AC(PCON) overcurrent active41 IPM board error communication42 IPM board gener

Page 12

Installation and operating instructions (translation of the orig-inal)Read these operating instructions carefully before commis-sioning / using this d

Page 13

Air filter for indoor unitClean the air filter at intervals of no more than 2weeks. Reduce this interval if the air is especiallydirty.Cleaning the fi

Page 14

11 Exploded view and spare parts lists 11.1 Exploded view indoor unit Fig. 19: Exploded view indoor unitWe reserve the right to modify the dimen

Page 15

11.2 Spare parts list - Indoor unit Please contact REMKO GmbH & Co. KG directly to order spare parts. All of the spare parts numbers for yourun

Page 16

No. Designation RKL 491 DCRKL 491 DC 30 Evaporator fanOn request by providing the serial number31 Compressor, cpl.32 Evaporator33 Coupling, set (1x m

Page 17 - Electrical connection

11.3 Exploded view outdoor unit Fig. 20: Exploded view outdoor unitWe reserve the right to modify the dimensions and design as part of the ongoing

Page 18

12 Index AAssemblyConnecting line... 14CCare and maintenance ... 19DDi

Page 21 - Exploded view indoor unit

ConsultingThanks to intensive training, our consultants are always completely up-to-date in terms of technical knowledge. This has given us the reputa

Page 22

Table of contents1 Safety and usage instructions...

Page 23

1 Safety andusage instructions 1.1 General safety notes Carefully read the operating manual before com-missioning the units for the first time.

Page 24

1.6 Safety notes for the operator The operational safety of the units and compo-nents is only assured providing they are used asintended and in a f

Page 25

1.11 Transport and packaging The devices are supplied in a sturdy shipping con-tainer. Please check the equipment immediatelyupon delivery and note

Page 26

2 Technical data 2.1 Technical data Unit dataSeries RKL 491 DCRKL 491 DC Operating mode Local inverter room air conditioner in split designN

Page 27

3 Structure and function Equipment descriptionThe device is particularly suited for flexible opera-tion, but can also be mounted in a stationary in

Page 28 - REMKO INTERNATIONAL

4 Operation The system can be operated by means of the control panel on the device or via the standard infrared remotecontrol unit. The functional