REMKO – powerful like a bear. REMKO VRS Universal oil/gas automatic heaters Edition GB – M10 Operation Technology Spare Parts
10 Prior to Initial Operation of the 400 V Series Fan Motor Operation Check the drive. 1. Check the rotational direction of the fan. 2. Check the
11 Unit Shut Down Starting Heating Mode 1. Turn the customer-supplied main switch or the fuse on. 2. Open the fuel supply. 3. If the unit is ta
12 1 2 3 4 5 6 7 3 2 4 5 1 shown. VRS 130 6+7 Cleaning the Combustion Chamber and the Heat-Exchanger of VRS 20 INOX Type Units: Option 1: (in th
13 The unit does not start 1. Check the power supply 2. Check the fuses in the control box. Only for units in the 400 V rotary current series. 3.
14 Technical Data VRS INOX 25 50 75 100 130 170 200 Rated heat power kW 33 62 89 125 160 208 249 Rated heat output kW 29 57 83 116
15 Technical Data VRS B REMKO VRS 40 60 80 120 150 210 250 310 380 450 Rated heat power kW 44 60 88 132 165 222 276 330 413 495 R
16 Technical Data VRS B 1) = Noise measuring (without burner) DIN 45635 -01 – KL3 REMKO VRS Rated pressure ∆p ext. Electric motor(s) Ventilator(en)
17 Wiring Diagram VRS 20 INOX Fan motor: 230 V / 1~ Burner motor: 230 V / 1~ We reserve the right to make modifications in dimensio
18 Wiring Diagram 230 V Fan motor: 230 V / 1~ Burner motor: 230 V / 1~ An easily accessible emergency swit
19 Fan motor: 400 V / 3~ Burner motor: 230 V / 1~ Wiring Diagram 400 V Direct Start An easily acc
20 Fan motor: 400 V / 3~ Burner motor: 230 V / 1~ Wiring Diagram 400 V ∆ / Y - Start We reser
21 Fan motor connection 400 V / 3~ Burner motor connection ( 3~ ) Connection to the thermal overcurrent relay on the burner motor Control voltage Bu
22 Exploded View VRS 20 INOX We reserve the right to make modifications in dimensions and construction in the interests of technical progress.
23 No. Description Ref. No. 1 Blow-out cover, cpl. (without blow-out grille) 359169 2 Blow-out grille (front) 1095343 3 Lining plate, left/righ
24 Fig. VRS 50 Replacement for No. 6 for design size 130 and higher Fig. Fan with belt operation Exploded View VRS INOX We reserve the right to make
25 No. Description 25 Inox Ref. No. 50 Inox Ref. No. 75 Inox Ref. No. 100 Inox Ref. No. 130 Inox Ref. No. 170 Inox Ref. No. 200 Inox Ref. No. 1 Unit
26 56987121110151425a/b20261327303132333428181924232122171623412935Exploded View VRS B Fig. VRS 80 upright model We reserve the right to make modifica
27 Spare Part List VRS B No. Description VRS 40 Ref. No. VRS 60 Ref. No. VRS 80 Ref. No. VRS 120 Ref. No. VRS 150 Ref. No. VRS 210 Ref. No. VRS 250 Re
28 Unit Dimensions VRS INOX Unit type (dimensions in mm) VRS 20 I VRS 25 I VRS 50 I VRS 75 I VRS 100 I VRS 130 I VRS 170 I VRS 200 I A 565 85
29 Unit Dimensions VRS B Unit type (dimensions in mm) VRS 40 VRS 60 VRS 80 VRS 120 VRS 150 VRS 210 VRS 250 VRS 310 VRS 380 VRS 450 A 825 10
3 Contents Page Safety Instructions 4 Description of th
30 Maintenance Log 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Clean unit -surface- Clean u
REMKO GmbH & Co. KG Klima- und Wärmetechnik D-32791 Lage • Im Seelenkamp 12 D-32777 Lage • PO Box 1827 Phone +49 (5232) 606 - 0 Fax +49 (5
4 ◊ The units may only be operated by persons who have received proper training in their operation. ◊ The units must be installed and operated in such
5 Selecting the Setup Location When selecting a location to set up the units, the re-quirements must be adjusted with respect to: ◊ Fire protection an
6 Important Information about Safe Setup ◊ The units may only be set up and operated in rooms where there is enough air for combustion and the ex-pell
7 Fuel Supply Particularly for heating oil lines, make sure that the cross-section of the lines corresponds to the suction height, the total line resi
8 w2 u2 v2w2 u2 v2w2 u2 v2u1 v1 w1u1 v1 w1u1 v1 w1L1L2L3L1L2L3L1L2L3Gas Connection Depending on the capacity of the unit, the required quantity of gas
9 G Make sure to maintain a safe distance to flamma-ble materials! Examples of Use Double-sided exhaust system / stainless-steel / outside assembly. A
Comments to this Manuals