10 Exploded View 1 16 17 7 11 12 29 30 31 24 26 27 25 28 33 34 36 37 37a 42 41 47 48 50 49 46 13 44 15 19 43 6 3 2 45 9 10 18 4 8 14 35 5 39 38 40 32
11 Spare Part List No. Description Ref.-No. 1 transport handle 1108131 2 inspection cover 1101801 3 protective socket, small 1102131 4 ignition
12 Wiring Diagram BS = operating switch NK = recool thermostat F = photo cell NTC = resistance HS =
13 Troubleshooting – unit does not start. – motor is running but burner will not be ignited. – unit stops during operation. fault LED of
14 Maintenance Log 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Clean unit -surface- Clean u
REMKO GmbH & Co. KG Klima- und Wärmetechnik D-32791 Lage • Im Seelenkamp 12 D-32777 Lage • PO Box 1827 Phone +49 (5232) 606 - 0 Fax +49 (
3 Contents Page Safety Instructions 4 Description of device
4 Description of Device The unit is fired directly with heating oil EL or diesel. It is intended for mobile and fully automatic deployment and operat
5 Provision for Air Heaters For the deployment of the unit, the relevant guidelines must be observed 1. Operating personnel 1.1 The unit must o
6 1 Installation Instructions The units are generally to be operated in accordance with the safety rules, the building code of the land con-cerned a
7 6 Attention, important hints to the after-cooling phase The air supply fan continues running to cool down the combustion chamber and then stops late
8 ◊ The unit is to be kept free from dust and other de-posits and is to be cleaned only with a dry or humid cloth. Do not use water jet. ◊ Do n
9 Cleaning the fuel tank It is necessary to clean the fuel tank: ◊ After each heating period or, depending on the deploy-ment conditions, even earlier