REMKO ETF 360/460
Automatic defrost
The moisture contained in the
room air condenses on cooling and
covers the evaporator fins with
frost or ice depending on the air
temperature and relative humidity
(% RH).
The automatic defrost function
integrated in the unit activates the
defrost cycle as required.
The frost or ice on the exchanger
surfaces can be defrosted using
hot gas as necessary.
This particularly fast and effective
defrost method guarantees a high
dehumidification capacity.
Dehumidification is interrupted
only briefly during the defrost
phase.
The indicator light [] shows that
the hot gas defrost cycle is active.
Emptying condensation
collector
The installed condensation
collector must be emptied from
time to time depending on the
amount of condensation produced.
When the condensation collector
is full, operation is interrupted and
the “Collector full” indicator light
[] flashes to show this status.
1. Carefully pull out the full
collector.
2. Empty the collector at a suitable
place.
3. Carefully place the emptied and
checked condensation collector
back in the unit.
s
s
s
Activate timer
With the timer function, automatic
“ON/OFF” switching functions
can be preselected up to 24 hours
(in a one hour cycle).
Timer switching functions
Adjustment during operation:
The unit switches OFF depending
on the selected number of hours.
Adjustment must be made with
the unit switched off (the mains
plug must be connected to a mains
socket).
The unit switches ON depending
on the selected number of hours.
The timer function can be
activated with the [] button
and the required time selected in
hour steps (max. 24 hours).
The entered value flashes in the
display [] for about 10 seconds.
An activated timer is indicated
constantly by the indicator light
[] at the control panel.
All programmed values/
settings are deleted when the
unit is disconnected from the
mains.
ATTENTION
!
At a sufficiently high room
temperature, no frost normally
forms on the fin surface,
obviating the need for
defrosting.
This makes the dehumidifier
operate highly efficiently.
NOTE
The unit will only start when
the condensation collector is
correctly seated.
NOTE
The unit cannot be controlled
via an external timer.
NOTE
After each emptying, the
condensate container including
float must be checked for pos-
sible damage, fouling, etc.
NOTE
The “Collector full“ indicator light
extinguishes and the unit continues
to operate fully automatically.