Troubleshooting
The units were manufactured using
the latest production methods
and tested repeatedly for perfect
function.
If faults should still occur, the unit
must initially be checked against
the following list.
The unit does not start:
Check The timer programming
Indicator light [] lit?
Check the mains connection and
local mains fuse -230V/1~/50
Hz
Check the mains plug and
power cord for damage
Check the level in the
condensation collector
Check for correct seating
The “Collector full” indicator
light [] must not fl ash!
Test the function of the
condensation collector
microswitch [MS].
Check for free air intake and
discharge
Overheating!
Check fuse on the control
board
This work makes it necessary
to open the unit which must
only be carried out by an
authorised specialist company.
5. Carefully clean the air fi lter [F]
with a soft brush or vacuum
cleaner.
6. A heavily clogged fi lter [F]
can be washed in a warm
(maximum 40°C) soap solution.
Subsequently rinse thoroughly
with clear water and allow to
dry!
7. The air inlet grille [G] must also
be checked for clogging and
cleaned if necessary.
8. Prior to refi tting, it must be
ensured that the air inlet
grille [G] and air fi lter [F]
are completely dry and
undamaged.
NOTE
Heavily fouled or damaged air
lters must be replaced with
new ones.
Only original spare parts must
be used.
NOTE
Repairs must only be carried
out by authorised specialists.
s
s
s
Filter cleaning
The unit is provided with an air
inlet grille with integrated air fi lter
to prevent damage.
To prevent a reduction in
performance and faults, the air
inlet grille with fi lter must be
checked as required, however at
least every two weeks and cleaned
if necessary.
1. Switch off the unit at the control
panel (button []).
2. Disconnect the mains plug from
the mains socket.
3. Remove the condensation
collector [K].
4. Pull out the air fi lter [F] located
behind the air inlet grille from
below.
The units must not be used
without air inlet grille and air
lter fi tted!
ATTENTION
!
All programmed values/
settings are deleted when the
unit is disconne cted from the
mains.
ATTENTION
!
K
F
G
F
F