Edition GB – W11
REMKO ML
ML 262 DC, ML 352 DC, ML 522 DC
Inverter wall mounted units in split design and
frost protection function
Operation · Technology · Spare parts
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - REMKO ML

Edition GB – W11REMKO MLML 262 DC, ML 352 DC, ML 522 DCInverter wall mounted units in split design and frost protection functionOperation · Technolog

Page 2

HEATING ModeDEHUMIDIFICATION MODEFAN SpeedFAN SpeedFAN SpeedSWING ButtonIt is recommended that the target temperature be set to 24 ° in dehumidifyi

Page 3 - Contents

SLEEP ButtonA programming function is activated using this button, which increases the target temperature in cooling mode by 1 °C after one hour and b

Page 4

There are individually adjustable fins for adjusting the horizontal air distribution on the air discharge side.Manual air distributionMoving, internal

Page 5 - Packaging

Cleaning the condensation pump (accessories)An optional integrated or separate condensation pump may be included with the indoor unit, which pumps out

Page 6

Troubleshooting and customer serviceThe equipment and components are manufactured using state-of-the-art production methods and tested several times t

Page 7 - Buttons on the remote control

Problem display by blinker codeInstallation instructions for qualified personnelImportant notes prior to installation Transport the unit in its origin

Page 8

Selection of the installation locationInterior unitThe indoor unit is designed for horizontal wall installation above doors. However, it can also be u

Page 9 - COOLING mode

1201500120120Installation inside buildings Ensure that heat can dissipate adequately when placing the outdoor component in cellars, attics, adjoining

Page 10 - REMKO ML...DC - ARCTIC

Connection variations1 Outlet on the wall, right2 Outlet through the wall, right3 Outlet through the wall, left4 Outlet on the wall, left1234Conne

Page 11

Supplementary information for Installation If the basic length of the refrigerant line exceeds 5 m, add refrigerant when commissioning the system fo

Page 13 - 1) see note

10 Slope of the condensation lineat least 2% slopeThe condensation hose is designed to be installed on the left side (viewed from the front).All e

Page 14

Connecting the outdoor componentProceed as follows to connect the cable:1. Remove the plastic panel at the connector.2. Select the cable cross-secti

Page 15

NUV~~~~+ +--Y/G34797FILTERHL1LH 2H 1NH 2NNLElectrical circuit diagramML 262-352 DC AT F1 = Condenser fanC1 = CompressorC1C1GLGLGLSTLP = Power boardST

Page 16

Electrical circuit diagramML 262-522 DC IT SNLY/GCN3SY/G34RY1CN6CN5 CN1NCN12CN8 CN11CN9CN73224L N SJX1I ON23CN4CN14CN13CN10P_137225CN2CN17F1 = Manual

Page 17

Add refrigerantThe equipment contains a basic quantity of refrigerant. Furthermore, for refrigerant line lengths of more than 5 metres per circuit, an

Page 18 - Connecting

Final tasks Reassemble all disassembled parts. Familiarise the operator with the system.4. If no leaks are found, open the stop valves by turning t

Page 19

Exploded view ML 262 DC IT to ML 522 DC ITWe reserve the right to modify the dimensions and constructional design as part of the ongoing technical de

Page 20

27Exploded view ML 262 DC AT to ML 522 DC ATWhen ordering spare parts, please state the computerised part no., device number and type of device (see i

Page 21 - Electrical connection diagram

REMKO ML...DC - ARCTIC28Performance data ML 262 DC35 37 39 4325 29 31 332.56 2.50 2.38 2.44 2.62 2.68 2.74 2.32 41 27 0.81 0.82 0.83 0

Page 22

29Performance data ML 522 DCCooling HeatingOutdoor temperature Outdoor temperature205.0 4.9 4.7 4.8 5.1 5.2 5.3 4.6 35 37 39 41 43 25 27 29 31

Page 23 - Electrical circuit diagram

ContentsRead these operating instructions carefully before commissioning / using the device! These instructions are an integral part of the system a

Page 24

REMKO ML...DC - ARCTIC30Technical dataSeriesML 262 DC ML 352 DC ML 522 DC Operational mode Wall / room air conditioner combination for cooling and h

Page 25 - Unit dimensions

31EC – Declaration of Conformity in accordance with the Machinery Directive, Annex II 1A Original Declaration of ConformityWe hereby declate that the

Page 26

Hotline +49 5232 606-0 Export+49 5232 606-130REMKO GmbH & Co. KG Air conditioning and heating technologyIm Seelenkamp 12 D-32791 Lage Postfach 1

Page 27 - Spare parts list

Safety notesDisposal of packagingAll products are packed for transport in environmentally friendly materials. Make a valuable contribution to reducing

Page 28

Equipment descriptionThe equipment is shipped in in sturdy transport packaging. Immediately check the equipment on delivery and make note of any damag

Page 29 - ML 522 DC

Display on indoor unitThe display illuminates according to the settings. vDisplay on indoor unitTimerAutomatic modeOperationDisplay Display of coded e

Page 30

30 minute intervals within the following 24 hours. "TIMER OFF" button This button serves to program the automatic shut-off time in 0.5 h i

Page 31

The remote control's on/off function is shown at the upper right of the remote control by a "wind symbol".Remote control on/offRESET Bu

Page 32 - REMKO INTERNATIONAL

▲/▼ ButtonsCooling modeAutomatic modeMODE ButtonUse the MODE button to select between individual operating modes. 5 modes are available:Using the butt