Technical data
2.1
Technical data
Unit data
Series RKL 491 DC
RKL 491 DC
Operating mode Local inverter room air conditioner in split design
Nominal cooling output
1)
kW 4.30 (1.80 to 4.60)
Energy efficiency ratio,
1)
B
Energy efficiency size SEER
1)
4.6
Power consumption, annual, Q
CE
kWh 346
Application area (room volume), approx. 120
Adjustment range indoor unit °C/%r.H. +16 to +30 / 35 to 80
Operating range outdoor unit °C/%r.H. +21 to +43 / 35 to 80
Refrigerant
R 410A
3)
Max. operating pressure kPa 4200
Air volume flow per level, indoor unit m³/h 380 / 520 / 600
Max. airflow volume outdoor unit m³/h 1000
Sound pressure level p. stage, ind. unit
2)
dB(A) 45 / 48 / 54
Sound power level max., IT/AT dB(A) 59 / 64
Power supply V/Hz 230 / 1~/ 50
Enclosure class indoor unit / outdoor unit IP 24 / X4
Electr. rated power consumption
1)
kW 1.31
Electr. rated current consumption
1)
A 5.60
Elec. starting current max., LRA A 8.00
Condensate pump, flow rate, max. mm WS 1800
Refrigerant, basic capacity kg 1.08
Refrigerant piping, length mm 3000, 2300 usable
Dimensions indoor unit H/W/D mm 695 / 470 / 335
Dimensions outdoor unit H/W/D mm 490 / 510 / 230
Weight indoor unit kg 35.0
Weight outdoor unit kg 14.0
Standard colour white silver
Serial number 1288... 1289...
EDP no. 1615490 1615491
1)
Air inlet temperature TK 27°C / FK 19°C, outside temperature TK 35 °C, FK 24 °C, max. air flow volume
2)
Distance 1m free field
3)
Contains greenhouse gas per Kyoto protocol (see also information in "Connecting line" chapter)